High-Temperature Monitoring × Explosion Protection × AI Vision × Industrial Systems IntegrationYour B2B Solutions Partner
MITSULITECHNOLOGY
B2B PRODUCT / SOLUTION

Infrared Gas Leak Detection Systems

Discuss infrared gas-leak monitoring for petrochemical and chemical facilities. Provide target gas, concentration, background and distance to assess sensor suitability.

Industrial Camera Systems

Miniature Explosion-Proof Thermal Camera for Leak Monitoring

Infrared Thermography Leak Detection System
MTL-Ex-MC-LK-C miniature explosion-proof thermal camera for leak monitoring
Thermography in VGA resolution

Features

  • 640 × 480 pixel
  • Radiometric video recording with 32 Hz / 125 Hz in subframe mode
  • Interchangeable lenses: 15°, 33°, 60°, 90°
PCB thermal monitoring example Equipment thermal monitoring example High-temperature equipment thermal monitoring example
MTL-Ex-MC-LK-C
Optical resolution640 × 480 pixel
DetectorFPA, uncooled (17 μm × 17 μm)
Spectral range7.5 – 13 μm
Temperature ranges−20–100°C, 0–250°C, 150–900°C,
200–1500°C
Frame rate32 Hz
Optics (FOV)33° × 25° FOV / f = 18.4 mm or
15° × 11° FOV / f = 41.5 mm or
60° × 45° FOV / f = 10.5 mm or
90° × 66° FOV / f = 7.3 mm
Thermal sensitivity (NETD)75 mK
Accuracy±2 °C or ±2 %, whichever is greater
PC interfaceUSB 2.0
Process interface (PIF), standard0 – 10 V input, digital input (max. 24 V), 0 – 10 V output
Process interface (PIF), industrial2× 0 – 10 V input, digital input (max. 24 V),
3× 0 – 10 V output, 3× relay (0 – 30 V / 400 mA), fail-safe relay
Cable length (USB)1 m (standard), 5 m, 10 m
5 m and 10 m also as HT cable (180 °C)
Ambient temperature−20 °C ~ 600 °C (1000 °C optional)
Relative humidity20 – 80 %, non-condensing
Shock / VibrationIEC 60068-2
Tripod mount¼ - 20 UNC

Engineering Requirements

Requirement Information to Provide
Operating Temperature Normal and maximum temperatures, and measurement locations
Installation Location Inside the furnace, at the furnace wall, outside equipment, on piping or elsewhere
Imaging Requirements Visible-light color, thermal, fixed, pan-tilt, 360° or mobile imaging
Communications Ethernet, 4G / Wi-Fi or integration with an existing monitoring system
Certification Requirements Explosion protection, ingress protection or other site-specific requirements

Next Steps

Describe Your Site ConditionsNo model selection required
Initial Engineering ReviewConfirm the appropriate system architecture
Solution & QuotationRecommendations based on specifications
Project ImplementationInstallation, testing and integration
ENGINEERING CONSULTATION

Infrared Gas Leak Detection Systems — Selection guidance

Share your site conditions and estimated quantity to discuss technical fit and next steps.

Start with your site challenge and contact details. Specifications can follow.

Industrial applications and selection

Gas-leak monitoring starts with matching the target gas to the detection principle. An infrared or thermal camera does not necessarily detect every gas; suitability depends on the specific sensor and conditions.

Information for engineering review

Provide gas species, concentration, distance, background temperature, airflow and area classification. Confirm sensitivity, certificates and interfaces with formal documentation and site validation.