Industrial Camera Systems
Miniature Explosion-Proof Thermal Camera for Leak Monitoring
Infrared Thermography Leak Detection System
Thermography in VGA resolution
Features
- 640 × 480 pixel
- Radiometric video recording with 32 Hz / 125 Hz in subframe mode
- Interchangeable lenses: 15°, 33°, 60°, 90°
MTL-Ex-MC-LK-C
| Optical resolution | 640 × 480 pixel |
|---|---|
| Detector | FPA, uncooled (17 μm × 17 μm) |
| Spectral range | 7.5 – 13 μm |
| Temperature ranges | −20–100°C, 0–250°C, 150–900°C, 200–1500°C |
| Frame rate | 32 Hz |
| Optics (FOV) | 33° × 25° FOV / f = 18.4 mm or 15° × 11° FOV / f = 41.5 mm or 60° × 45° FOV / f = 10.5 mm or 90° × 66° FOV / f = 7.3 mm |
| Thermal sensitivity (NETD) | 75 mK |
| Accuracy | ±2 °C or ±2 %, whichever is greater |
| PC interface | USB 2.0 |
| Process interface (PIF), standard | 0 – 10 V input, digital input (max. 24 V), 0 – 10 V output |
| Process interface (PIF), industrial | 2× 0 – 10 V input, digital input (max. 24 V), 3× 0 – 10 V output, 3× relay (0 – 30 V / 400 mA), fail-safe relay |
| Cable length (USB) | 1 m (standard), 5 m, 10 m 5 m and 10 m also as HT cable (180 °C) |
| Ambient temperature | −20 °C ~ 600 °C (1000 °C optional) |
| Relative humidity | 20 – 80 %, non-condensing |
| Shock / Vibration | IEC 60068-2 |
| Tripod mount | ¼ - 20 UNC |
Engineering Requirements
| Requirement | Information to Provide |
|---|---|
| Operating Temperature | Normal and maximum temperatures, and measurement locations |
| Installation Location | Inside the furnace, at the furnace wall, outside equipment, on piping or elsewhere |
| Imaging Requirements | Visible-light color, thermal, fixed, pan-tilt, 360° or mobile imaging |
| Communications | Ethernet, 4G / Wi-Fi or integration with an existing monitoring system |
| Certification Requirements | Explosion protection, ingress protection or other site-specific requirements |
Next Steps
Describe Your Site ConditionsNo model selection required
Initial Engineering ReviewConfirm the appropriate system architecture
Solution & QuotationRecommendations based on specifications
Project ImplementationInstallation, testing and integration
ENGINEERING CONSULTATION
Infrared Gas Leak Detection Systems — Selection guidance
Share your site conditions and estimated quantity to discuss technical fit and next steps.
Start with your site challenge and contact details. Specifications can follow.Industrial applications and selection
Gas-leak monitoring starts with matching the target gas to the detection principle. An infrared or thermal camera does not necessarily detect every gas; suitability depends on the specific sensor and conditions.
Information for engineering review
Provide gas species, concentration, distance, background temperature, airflow and area classification. Confirm sensitivity, certificates and interfaces with formal documentation and site validation.