High-Temperature Monitoring × Explosion Protection × AI Vision × Industrial Systems IntegrationYour B2B Solutions Partner
MITSULITECHNOLOGY
B2B PRODUCT / SOLUTION

Infrared Gas Leak Detection Systems

Assess the implementation requirements and next steps for infrared gas leak detection systems.

Industrial Camera Systems

Miniature Explosion-Proof Thermal Camera for Leak Monitoring

Infrared Thermography Leak Detection System
MTL-Ex-MC-LK-C miniature explosion-proof thermal camera for leak monitoring
Thermography in VGA resolution

Features

  • 640 × 480 pixel
  • Radiometric video recording with 32 Hz / 125 Hz in subframe mode
  • Interchangeable lenses: 15°, 33°, 60°, 90°
PCB thermal monitoring example Equipment thermal monitoring example High-temperature equipment thermal monitoring example
MTL-Ex-MC-LK-C
Optical resolution640 × 480 pixel
DetectorFPA, uncooled (17 μm × 17 μm)
Spectral range7.5 – 13 μm
Temperature ranges−20–100°C, 0–250°C, 150–900°C,
200–1500°C
Frame rate32 Hz
Optics (FOV)33° × 25° FOV / f = 18.4 mm or
15° × 11° FOV / f = 41.5 mm or
60° × 45° FOV / f = 10.5 mm or
90° × 66° FOV / f = 7.3 mm
Thermal sensitivity (NETD)75 mK
Accuracy±2 °C or ±2 %, whichever is greater
PC interfaceUSB 2.0
Process interface (PIF), standard0 – 10 V input, digital input (max. 24 V), 0 – 10 V output
Process interface (PIF), industrial2× 0 – 10 V input, digital input (max. 24 V),
3× 0 – 10 V output, 3× relay (0 – 30 V / 400 mA), fail-safe relay
Cable length (USB)1 m (standard), 5 m, 10 m
5 m and 10 m also as HT cable (180 °C)
Ambient temperature−20 °C ~ 600 °C (1000 °C optional)
Relative humidity20 – 80 %, non-condensing
Shock / VibrationIEC 60068-2
Tripod mount¼ - 20 UNC

At a Glance

Operating Environment

High-temperature, hazardous, dusty or continuous-process environments requiring remote visual monitoring.

Key Benefits

Improve process visibility, reduce personnel exposure and relay anomaly information to the monitoring center.

Integration Options

Networks, alarms, thermal imaging, AI vision and centralized monitoring can be configured to suit project requirements.

Engineering Requirements

Requirement Information to Provide
Operating Temperature Normal and maximum temperatures, and measurement locations
Installation Location Inside the furnace, at the furnace wall, outside equipment, on piping or elsewhere
Imaging Requirements Visible-light color, thermal, fixed, pan-tilt, 360° or mobile imaging
Communications Ethernet, 4G / Wi-Fi or integration with an existing monitoring system
Certification Requirements Explosion protection, ingress protection or other site-specific requirements

Next Steps

Describe Your Site ConditionsNo model selection required
Initial Engineering ReviewConfirm the appropriate system architecture
Solution & QuotationRecommendations based on specifications
Project ImplementationInstallation, testing and integration

Need Help Selecting a Solution?

Share the operating temperature, viewing distance, site photos, equipment application and requirements for an initial assessment.

Request an Engineering Assessment