High-Temperature Monitoring × Explosion Protection × AI Vision × Industrial Systems IntegrationYour B2B Solutions Partner
MITSULITECHNOLOGY
B2B PRODUCT / SOLUTION

Explosion-Proof Dust Concentration Detection System

Review MIT-Ex-DCD PM2.5/PM10 monitoring and 4–20 mA or RS485 MODBUS RTU interfaces. Assess mounting, dust conditions and hazardous-area requirements.

Industry Camera System Industrial Surveillance Camera System

Explosion-Proof Dust Concentration Detection System

Explosion-Proof Dust Concentration Detection System

MIT-Ex-DCD
MIT-Ex-DCD Explosion-Proof Dust Concentration Detection System
Exd IIB Gb / Ex tb IIIC Db

Product Features

  • Uses advanced semiconductor nanotechnology with low power consumption, a 32-bit microprocessor and a 24-bit ADC data chip.
  • Equipped with a 2.0-inch industrial-grade display with 320×240 resolution.
  • Concentration units can be switched between ug/m³ and mg/m³.
  • LCD displays concentration, type, unit and operating status.
  • Independent sensing chamber; sensor replacement does not require on-site setup, and key parameters are identified automatically.
  • Two-stage alarm setting with dual relay signal outputs: two sets of dry-contact NO/NC outputs.
  • Multiple signal outputs are supported: standard 4–20 mA output with transmission distance <1 km; standard RS485 signal using MODBUS RTU with transmission distance <1 km.
  • Provides pressure resistance, lightning, short-circuit, reverse-polarity, electrostatic and magnetic-interference protection, plus automatic recovery to reduce damage from external, human or natural causes.
  • Explosion-proof certification: Exd IIB Gb / Ex tb IIIC Db.

Specifications

DetectorPM2.5、PM10
Detection MethodLaser scattering
InstallationWall-mounted or pipe-connected (thread: G1/2)
Measurement Range(0-1000)ug/m³、(0-6000)ug/m³
Resolution1 ug/m³
Operating VoltageDC24V±15%
Detection Accuracy≤±10%F.SLinearity Error≤±5%F.S
Response Time≤10 s (T90)Zero Drift≤±2%F.S/year
Recovery Time≤30 sRepeatability≤±2%F.S
RelayTwo relay outputs; contact capacity: 30VDC 2A / 125VAC 1A
Explosion-Proof MarkingExd IIB Gb / Ex tb IIIC Db
Protection RatingIP66Cable EntryM20x1.5、G1/2
Enclosure MaterialCopper-free aluminum alloyWorking Pressure86~106Kpa
Operating Humidity≤95%RH, non-condensingOperating Temperature-20~55°C

Engineering Requirements

Requirement Information to Provide
Operating Temperature Normal and maximum temperatures, and measurement locations
Installation Location Inside the furnace, at the furnace wall, outside equipment, on piping or elsewhere
Imaging Requirements Visible-light color, thermal, fixed, pan-tilt, 360° or mobile imaging
Communications Ethernet, 4G / Wi-Fi or integration with an existing monitoring system
Certification Requirements Explosion protection, ingress protection or other site-specific requirements

Next Steps

Describe Your Site ConditionsNo model selection required
Initial Engineering ReviewConfirm the appropriate system architecture
Solution & QuotationRecommendations based on specifications
Project ImplementationInstallation, testing and integration
ENGINEERING CONSULTATION

Explosion-Proof Dust Concentration Detection System — Selection guidance

Share your site conditions and estimated quantity to discuss technical fit and next steps.

Start with your site challenge and contact details. Specifications can follow.

Industrial applications and selection

MIT-Ex-DCD documentation describes laser-scattering detection for PM2.5 and PM10. Suitability depends on particle size, concentration and the industrial environment.

Information for engineering review

Provide wall or pipe mounting needs, dust material, temperature, humidity and area classification. Check control-system inputs and wiring; applicable areas depend on the product certificate.

Engineering reviewLINE consultation