High-Temperature Monitoring × Explosion Protection × AI Vision × Industrial Systems IntegrationYour B2B Solutions Partner
MITSULITECHNOLOGY
B2B PRODUCT / SOLUTION

Waterproof 4G / Wi-Fi Dome Cameras

Assess the implementation requirements and next steps for waterproof 4G / Wi-Fi dome cameras.

Portable Waterproof 4G / Wi-Fi Dome Camera

Waterproof 4G / Wi-Fi Camera System

MTL-4G-WP-SPD portable waterproof 4G / Wi-Fi dome camera

Key Features

  • IP66 ingress protection; IK10 impact resistance
  • 4-megapixel imaging, enhanced wide dynamic range and H.265 video compression
  • Day/night imaging with enhanced low-light sensitivity and smart IR LEDs
  • PTZ auto-tracking, continuous pan/tilt operation, motorized zoom and autofocus
  • Rechargeable lithium-ion battery; 10–15 hours of operation (source rating: 9800 mA; battery capacity unit to be confirmed)
  • Wireless 4G / Wi-Fi transmission with real-time on-camera recording for mobile use
  • 25× optical zoom; continuous 360° pan; 120° vertical adjustment bracket (optional)
General
Power SourceDC 12V, High PoE (IEEE802.3at)
Power Consumption21 W (PoE)
Operating Temperature-40°C ~ 65°C (-40°F ~ 149°F)
Environmental CasingIngress protection: IP66; impact resistance: IK10
ApprovalsCE Class B, FCC Class B, IP66, IK10
Weight7.5Kg (Tripod included)
4G LTE Wireless ModuleLTE-Cat.4、2 × SIM;2 × RJ45FE (WAN/LAN);LTE/Ethernet/Wi-Fi failover;IEEE 802.11n;IPSec / OpenVPN / PPTP / L2TP / GRE;APN
Rechargeable Lithium Battery Power SystemRechargeable lithium battery system: DC 12 V, source rating 9800 mA (capacity unit to be confirmed); 10–15 hours of continuous operation
Support / TripodHigh-strength aluminum-alloy or carbon-fiber construction (optional)
MTL-4G-WP-SPD
Device
Maximum Resolution4MP
Image SensorProgressive Scan CMOS
Sensor Size1/2.8"
Day / NightYes
Low Light SensitivitySuperior
Minimum IlluminationColor: 0.003 lux at F1.5 (AGC on); B/W: 0 (IR LED on)
IR LEDAdaptive IR LED; 150m (1.0 lux at tele mode)
Electronic Shutter1-1/100000 second (manual mode); 1-1/100000 second (auto mode)
S/N Ratio56 dB
Lens
Focal LengthZoom, f4.8-120mm
ApertureF1.5-F3.8
Zoom Ratio25x optical zoom, unlimited digital zoom (via web browser)
Iris & FocusAuto iris & Auto focus
Horizontal Viewing Angle55.3° - 3.2°
Vertical Viewing Angle56° - 2.1°
PTZ
Manual Panning / Tilting Speed0.1° - 200°/second, 0.1° - 120°/second
Preset Panning / Tilting Speed240°/second, 200°/second
Panning Range360° endless
Tilting Range-15°~90° (with E-flip)
PTZ ControlRemote manual control, 1024 preset points, 16 preset tours
Pan, Tilt or Zoom protocolPelco-D, Pelco-P
Video
CompressionH.265, H.264, MJPEG
Maximum Frame Rate by Resolution30 fps at 2688×1520; 30 fps at 2560×1440; 30 fps at 1920×1080; 30 fps at 1280×720; 30 fps at 720×576; 30 fps at 704×288; 30 fps at 640×360; 30 fps at 352×288
Multi-StreamingSimultaneous triple streams
Wide Dynamic RangeSuperior WDR (120 dB)
Image EnhancementWhite Balance, Backlight compensation (BLC), Defogging
Digital Noise Reduction2D + 3D DNR
Privacy Mask24 configurable regions
Image OrientationFlip, Mirror, Rotation (Corridor mode)
Network
Network Protocol & ServiceIPv4, TCP, UDP, DHCP, PPPoE, HTTP, HTTPS, DNS, DDNS, NTP, RTP, RTSP, RTCP, SMTP, FTP, IGMP, ICMP, ARP, UPnP, QoS, SSL/TLS, IEEE 802.1X
Ethernet Port1 × Ethernet (10/100 Base-T), RJ-45 connector
SecurityIP address filtering, HTTPS encryption, password protected user level, IEEE 802.1X network access control
Integration
ONVIF CompliantProfile S, Profile G, Profile T
Interface
Serial Port1 × RS-485
Analog Video Output1 × BNC connector
Local StoragemicroSD card slot; optional storage listed as 256 Gb in the source (capacity unit to be confirmed)

At a Glance

Operating Environment

High-temperature, hazardous, dusty or continuous-process environments requiring remote visual monitoring.

Key Benefits

Improve process visibility, reduce personnel exposure and relay anomaly information to the monitoring center.

Integration Options

Networks, alarms, thermal imaging, AI vision and centralized monitoring can be configured to suit project requirements.

Engineering Requirements

Requirement Information to Provide
Operating Temperature Normal and maximum temperatures, and measurement locations
Installation Location Inside the furnace, at the furnace wall, outside equipment, on piping or elsewhere
Imaging Requirements Visible-light color, thermal, fixed, pan-tilt, 360° or mobile imaging
Communications Ethernet, 4G / Wi-Fi or integration with an existing monitoring system
Certification Requirements Explosion protection, ingress protection or other site-specific requirements

Next Steps

Describe Your Site ConditionsNo model selection required
Initial Engineering ReviewConfirm the appropriate system architecture
Solution & QuotationRecommendations based on specifications
Project ImplementationInstallation, testing and integration

Need Help Selecting a Solution?

Share the operating temperature, viewing distance, site photos, equipment application and requirements for an initial assessment.

Request an Engineering Assessment